Endress Hauser Proline Promag H 500 Electromagnetic Flowmeter 5H5B02 5H5B1F 5H5B1H
The Proline Promag H 500 is an electromagnetic flowmeter from Endress+Hauser, designed as a specialist for hygienic applications with the highest requirements in the food and beverage and life sciences industries. Featuring a remote transmitter with up to 4 I/Os, it maximizes installation flexibility and operational safety in demanding environments.
Key Features and Benefits
-
Dedicated to Hygienic Applications: The sensor is designed for the food and beverage and life sciences industries, with a stainless steel housing and wetted materials that are CIP and SIP cleanable. It holds 3-A and EHEDG sanitary approvals, with FDA and cGMP compliance.
-
Multivariable Measurement: Simultaneously measures volume flow, temperature, conductivity, mass flow, and corrected volume flow/conductivity, providing comprehensive process data from a single device.
-
Flexible Remote Installation: The remote version offers up to 4 I/Os with a hygienic sensor connection housing rated up to IP69 for demanding washdown environments.
-
Maintenance-Free and Energy-Efficient: The bidirectional measuring principle has no moving parts, ensuring maintenance-free operation with no pressure loss due to cross-section constriction.
-
Wide Material Selection: Liner is made of PFA, with electrode materials available in 1.4435 (316L), Alloy C22, Tantalum, and Platinum, ensuring compatibility with various hygienic process media.
-
Built-in Heartbeat Technology: Integrated verification ensures measurement reliability, enables compliant verification according to ISO 9001 (TÜV-attested), and allows extension of recalibration cycles.
Technical Specifications (at a Glance)
| Specification | Detail |
|---|---|
| Measuring Principle | Electromagnetic |
| Nominal Diameter Range | DN 2 to 150 (¹⁄₁₂ to 6″) |
| Measured Variables | Volume flow, temperature, conductivity, mass flow, corrected volume flow, corrected conductivity |
| Max. Measurement Error | Standard: ±0.5% o.r. ± 1 mm/s; Option: ±0.2% o.r. ± 2 mm/s |
| Measuring Range | 0.06 dm³/min to 600 m³/h (0.015 to 2,650 gal/min) |
| Max. Process Pressure | PN 40, Class 150, 20K |
| Medium Temperature Range | –20 to +150 °C (–4 to +302 °F) |
| Liner Material | PFA |
| Electrode Materials | 1.4435 (316L); Alloy C22; Tantalum; Platinum |
| Sensor Housing Material | 1.4301 (304) stainless steel (3-A, EHEDG) |
| Degree of Protection | Sensor standard: IP66/67, Type 4X; Option: IP69 |
| Digital Communication | HART, PROFIBUS DP/PA, FOUNDATION Fieldbus, Modbus RS485, PROFINET, EtherNet/IP, OPC-UA |
| Hygienic Approvals | 3-A, EHEDG, FDA, cGMP |
The Proline Promag H 500 delivers reliable, high-accuracy flow measurement for demanding hygienic applications, combining a flexible remote transmitter design with multivariable measurement, comprehensive communication options, and advanced diagnostic capabilities through Heartbeat Technology.
Endress Hauser Proline Promag H 500 Electromagnetic Flowmeter 5H5B02 5H5B1F 5H5B1H
The Proline Promag H 500 is an electromagnetic flowmeter from Endress+Hauser, engineered as a specialist for hygienic applications with the highest requirements in the food and beverage and life sciences industries . Featuring a remote transmitter with up to 4 I/Os, this instrument maximizes installation flexibility and operational safety in demanding washdown environments .
The meter operates on the electromagnetic measuring principle, measuring flow bidirectionally with no moving parts . This design ensures maintenance-free operation and energy-efficient measurement without pressure loss caused by cross-section constriction . The nominal diameter range covers DN 2 to 150 (¹⁄₁₂ to 6 inches), with measuring capabilities from 0.06 dm³/min to 600 m³/h (0.015 to 2,650 gal/min) .
The sensor housing is constructed entirely of stainless steel (1.4301 / 304), with wetted materials designed for CIP and SIP cleaning . The liner is made of PFA, and electrode materials are available in 1.4435 (316L) stainless steel, Alloy C22, Tantalum, and Platinum, ensuring compatibility with a wide variety of hygienic process media . The device holds 3-A and EHEDG sanitary approvals, with liner and seals meeting FDA and cGMP standards for compliance with hygienic requirements . Medium temperature range is –20 to +150°C (–4 to +302°F) .
In addition to volume flow, the Promag H 500 simultaneously measures temperature, conductivity, mass flow, corrected volume flow, and corrected conductivity, providing comprehensive multivariable process data from a single instrument . Measurement accuracy is specified at ±0.5% of reading ± 1 mm/s for standard applications, with an optional high-accuracy version at ±0.2% of reading ± 2 mm/s .
The remote transmitter offers flexible installation with up to 4 I/Os, enabling extensive connectivity for various process requirements . Local operation is intuitive, with a backlit display featuring touch control and WLAN access . Digital communication options include HART, PROFIBUS DP/PA, FOUNDATION Fieldbus, Modbus RS485, PROFINET, EtherNet/IP, and OPC-UA, ensuring seamless integration into a wide range of control systems . The sensor housing is rated IP66/67, Type 4X enclosure as standard, with an optional IP69 rating for demanding washdown environments .
Integrated Heartbeat Technology enables continuous process safety monitoring and compliance verification, with TÜV-attested verification in accordance with ISO 9001 . This technology allows extension of recalibration cycles and provides proof of measurement reliability without process interruption .
The Proline Promag H 500 delivers reliable, high-accuracy flow measurement for demanding hygienic applications, combining a flexible remote transmitter design, multivariable measurement, comprehensive communication options, and advanced diagnostic capabilities through Heartbeat Technology.