Endress Hauser Proline Prowirl D 200 Vortex Flowmeter 7D2C15 7D2C1F 7D2C1H
The Proline Prowirl D 200 is a cost-effective wafer-style vortex flowmeter from Endress+Hauser, optimized for wet, saturated, and superheated steam, gases, and liquids, including cryogenic applications. Featuring genuine loop-powered two-wire technology and a robust, drift-free capacitive DSC sensor, it enables seamless integration into existing infrastructures while offering superior long-term stability and operational safety in hazardous areas.
Key Features and Benefits
-
Cost-Effective Wafer Design: The sensor installs directly between two flanges with a compact face-to-face length of 65 mm (2.56 in), eliminating the need for flanges and reducing weight and installation costs. It is ideal for ancillary process applications and 1-to-1 replacement of orifice plates.
-
Optimized for Steam Applications: Integrated temperature measurement enables mass flow and energy flow calculation for saturated steam. The Prowirl D 200 is the preferred measuring principle for wet, saturated, and superheated steam, gases, and liquids.
-
High Robustness and Long-Term Stability: The capacitive DSC sensor is drift-free and proven to withstand vibrations, temperature shocks, and water hammer, ensuring long-term stability without recalibration.
-
Easy Installation and Operation: The sensor includes centering rings for easy alignment during installation. The transmitter features a separate connection compartment for convenient wiring and a 4-line backlit display with touch control for safe operation without opening the device.
-
Built-in Heartbeat Technology: Integrated verification ensures measurement reliability, enables compliant verification according to ISO 9001:2015, and allows extension of recalibration cycles without process interruption.
Technical Specifications (at a Glance)
| Specification | Detail |
|---|---|
| Measuring Principle | Vortex (Karman vortex street) |
| Nominal Diameter Range | DN 15 to 150 (½ to 6″) |
| Measured Variables | Volume flow, mass flow, corrected volume flow, energy flow, heat flow difference, temperature |
| Max. Measurement Error | Liquid volume flow: ±0.75%; Steam/gas volume flow: ±1.00%; Liquid mass flow: ±0.85%; Steam/gas mass flow: ±1.7% |
| Measuring Range | Liquid: 0.16 to 625 m³/h; Steam/gas: 2 to 8,342 m³/h |
| Max. Process Pressure | PN 40, Class 300, 20K |
| Medium Temperature Range | Standard: –40 to +260°C; Option: –200 to +400°C; Special: –200 to +450°C |
| Wetted Materials | Measuring tube: 1.4408 (CF3M); DSC sensor: 1.4435 (316/316L) |
| Transmitter Housing | AlSi10Mg coated; 1.4404 (316L) |
| Degree of Protection | IP66/67, Type 4X enclosure |
| Display/Operation | 4-line backlit display with touch control; remote display available |
| Digital Communication | HART, PROFIBUS PA, FOUNDATION Fieldbus, PROFINET over Ethernet-APL, Modbus TCP over Ethernet-APL |
| Power Supply | DC 12 to 35 V (4-20 mA HART); DC 9 to 32 V (PROFIBUS PA) |
| Functional Safety | IEC 61508 (SIL), applicable in IEC 61511 safety applications |
| Hazardous Area Approvals | ATEX, IECEx, cCSAus, JPN, EAC, UK Ex, KC |
The Proline Prowirl D 200 delivers reliable, cost-effective vortex flow measurement for demanding steam, gas, and liquid applications, combining a compact wafer design, robust construction, maintenance-free operation, and the advanced diagnostic power of Heartbeat Technology.