Endress Hauser Proline Promass P 100 Coriolis Flowmeter 8P1B15 8P1B25 8P1B40

The Proline Promass P 100 is a Coriolis flowmeter from Endress+Hauser, designed as the specialist for life sciences applications with an ultra-compact transmitter. Dedicated to sterile processes and demanding hygienic environments, it delivers full performance on the smallest footprint, making it the preferred choice for system integrators, skid builders, and equipment manufacturers.

Key Features and Benefits

  • Specialist for Life Sciences and Sterile Applications: The Promass P 100 is engineered for applications under sterile conditions in the life sciences and pharmaceutical industries. It is ASME BPE, 3-A, and EHEDG compliant with low delta ferrite, featuring an electropolished measuring tube in 1.4435 (316L) and fast recovery from CIP/SIP cycles.

  • Ultra-Compact Transmitter: The device features the smallest transmitter housing available today, providing full functionality on a minimal footprint for space-constrained installations.

  • Multivariable Measurement: Simultaneously measures mass flow, density, temperature, volume flow, corrected volume flow, reference density, and concentration, reducing the need for multiple process measuring points.

  • High Accuracy: Delivers a mass flow accuracy of ±0.1% for liquids, with density accuracy of ±0.0005 g/cm³.

  • Convenient Operation and Verification: Integrated web server enables time-saving local operation without additional software or hardware. Built-in Heartbeat Technology provides integrated verification and diagnostics.

Technical Specifications (at a Glance)

Specification Detail
Measuring Principle Coriolis
Nominal Diameter Range DN 8 to 50 (⅜ to 2″)
Measured Variables Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentratio
Max. Measurement Error Mass flow (liquid): ±0.1%; Density: ±0.0005 g/cm³
Measuring Range 0 to 70,000 kg/h (0 to 2,570 lb/min)
Max. Process Pressure PN 63, Class 300, 40K
Medium Temperature Range Standard: –50 to +150°C; Option: –50 to +205°C
Wetted Materials Measuring tube: 1.4435 (316L); Connections: 1.4435 (316L); 1.4404 (316/316L)
Transmitter Housing AlSi10Mg, coated
Degree of Protection IP66/67, Type 4X enclosure; IP69 optional
Display/Operation 4-line backlit display available; Configuration via web browser
Digital Communication HART, Modbus RS485, EtherNet/IP, PROFIBUS DP, PROFINET
Power Supply DC 20 to 30 V
Hygienic Approvals 3-A, EHEDG, ASME BPE, ISPE, cGMP
Hazardous Area Approvals ATEX, IECEx, cCSAus, INMETRO, NEPSI, EAC

The Proline Promass P 100 delivers reliable, high-performance Coriolis flow measurement for demanding life sciences and sterile applications, combining an ultra-compact transmitter, multivariable measurement capability, hygienic compliance, and the diagnostic power of Heartbeat Technology.

Endress Hauser Proline Promass P 100 Coriolis Flowmeter 8P1B15 8P1B25 8P1B40

 

The Proline Promass P 100 is a Coriolis flowmeter from Endress+Hauser, designed as the specialist for life sciences applications with an ultra-compact transmitter. Dedicated to sterile processes and demanding hygienic environments, it delivers full performance on the smallest footprint, making it the preferred choice for system integrators, skid builders, and equipment manufacturers.

The meter operates on the Coriolis measuring principle, where two measuring tubes oscillate in antiphase and the Coriolis force creates a phase shift proportional to mass flow. This direct measurement is virtually independent of pressure, density, temperature, and viscosity, ensuring robust performance. The nominal diameter range covers DN 8 to 50 (³⁄₈ to 2 inches), with measuring capabilities from 0 to 70,000 kg/h (0 to 2,570 lb/min).

The device provides multivariable measurement, simultaneously capturing mass flow, density, temperature, volume flow, corrected volume flow, reference density, and concentration. Mass flow accuracy for liquids is ±0.1%, and density accuracy is ±0.0005 g/cm³. The measuring principle requires no inlet or outlet straight pipe runs, enabling space-saving installation. Medium temperature range is –50 to +150°C as standard, with an optional high-temperature version extending to +205°C. Maximum process pressure reaches PN 63, Class 300, or 40K.

Wetted materials are selected for sterile and hygienic compliance. Measuring tubes are constructed of 1.4435 (316L) with electropolished surface finish and low delta ferrite, and process connections are available in 1.4435 (316L) and 1.4404 (316/316L). The device complies with ASME BPE, 3-A, and EHEDG standards, ensuring suitability for pharmaceutical and biotech applications. It features fast recovery from CIP/SIP cycles, enhancing process availability.

The ultra-compact transmitter provides full functionality on the smallest footprint, ideal for space-constrained installations. Transmitter housing is constructed of coated AlSi10Mg and is rated IP66/67, Type 4X enclosure, with an optional IP69 rating for demanding washdown environments. A 4-line backlit display is available for local operation, and configuration is accessible via an integrated web server without additional software or hardware. Digital communication options include HART, Modbus RS485, EtherNet/IP, PROFIBUS DP, and PROFINET.

Integrated Heartbeat Technology enables continuous process safety monitoring and traceable verification without process interruption. The device holds international hazardous area approvals including ATEX, IECEx, cCSAus, INMETRO, NEPSI, and EAC, and is compliant with hygienic standards including 3-A, EHEDG, ASME BPE, ISPE, and cGMP.

The Proline Promass P 100 delivers reliable, high-performance Coriolis flow measurement for demanding life sciences and sterile applications, combining an ultra-compact transmitter, multivariable measurement capability, hygienic compliance, and the diagnostic power of Heartbeat Technology.