Endress Hauser Proline Promass F 100 Coriolis Flowmeter 8F1B08 8F1B1F 8F1B1H
The Proline Promass F 100 is a premium Coriolis flowmeter from Endress+Hauser, engineered with an ultra-compact transmitter for high-accuracy measurement of liquids and gases under varying, demanding process conditions. Featuring a robust, space-saving design and integrated multivariable measurement, it is the preferred choice for system integrators, skid builders, and equipment manufacturers.
Key Features and Benefits
-
Premium Accuracy and Robustness: Offers a standard liquid mass flow accuracy of ±0.10%, with an optional PremiumCal upgrade to ±0.05%. Immune to fluctuating and harsh environments, ensuring process safety under demanding conditions.
-
Multivariable Measurement: Simultaneously measures mass flow, density, temperature, volume flow, corrected volume flow, reference density, and concentration, reducing the need for multiple process measuring points.
-
Ultra-Compact and Space-Saving Design: The transmitter provides full functionality on the smallest footprint, saving valuable installation space. The measuring principle requires no inlet or outlet straight pipe runs.
-
Wide Material and Temperature Options: Wetted materials include 1.4539 (904L), 1.4404 (316/316L), and Alloy C22, 2.4602 (UNS N06022). Medium temperature range from –50 to +150 °C as standard, with an optional high-temperature version up to +240 °C.
-
Convenient Commissioning and Operation: An integrated web server enables time-saving local configuration without additional software or hardware. Robust transmitter housing offers IP66/67, Type 4X protection, with an optional IP69 rating.
-
Integrated Heartbeat Technology: Built-in verification ensures measurement reliability, enables traceable verification according to ISO 9001:2015 (TÜV SÜD attestation), and allows extension of recalibration cycles.
Technical Specifications (at a Glance)
| Specification | Detail |
|---|---|
| Measuring Principle | Coriolis |
| Nominal Diameter Range | DN 8 to 250 (³⁄₈ to 10″) |
| Measured Variables | Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration |
| Max. Measurement Error | Mass flow (liquid): ±0.1% (standard), ±0.05% (PremiumCal); Mass flow (gas): ±0.25%; Density (liquid): ±0.0005 g/cm³ |
| Measuring Range | 0 to 2,200,000 kg/h (0 to 80,840 lb/min) |
| Max. Process Pressure | PN 100, Class 600, 63K |
| Medium Temperature Range | Standard: –50 to +150 °C; Option: –50 to +240 °C |
| Wetted Materials | Measuring tube: 1.4539 (904L); 1.4404 (316/316L); Alloy C22, 2.4602 |
| Sensor Housing Material | 1.4301/1.4307 (304L), corrosion resistant |
| Transmitter Housing | AlSi10Mg, coated; 1.4301 (304), 1.4404 (316L) |
| Degree of Protection | IP66/67, Type 4X enclosure; IP69 optional |
| Display/Operation | 4-line backlit display available; Configuration via web browser |
| Digital Communication | HART, Modbus RS485, EtherNet/IP, PROFIBUS DP, PROFINET |
| Power Supply | DC 20 to 30 V |
| Hazardous Area Approvals | ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC |
| Hygienic Approvals | 3-A, EHEDG, cGMP |
| Marine Approvals | ABS, BV, LR, CCS |
| Material Certificates | 3.1 material; NACE MR0175/MR0103 |
The Proline Promass F 100 delivers premium measurement performance for liquids and gases under varying, demanding process conditions, combining high accuracy, a robust ultra-compact design, multivariable measurement capability, and the diagnostic power of Heartbeat Technology.
Endress Hauser Proline Promass F 100 Coriolis Flowmeter 8F1B08 8F1B1F 8F1B1H
The Proline Promass F 100 is a premium Coriolis flowmeter from Endress+Hauser, engineered with an ultra-compact transmitter for high-accuracy measurement of liquids and gases under varying, demanding process conditions. Featuring a robust, space-saving design and integrated multivariable measurement, it is the preferred choice for system integrators, skid builders, and equipment manufacturers.
The meter operates on the Coriolis measuring principle, where two curved measuring tubes oscillate in antiphase and the Coriolis force creates a phase shift proportional to mass flow. This direct measurement is virtually independent of pressure, density, temperature, and viscosity, ensuring robust performance under fluctuating and harsh conditions. The nominal diameter range covers DN 8 to 250 (⅜ to 10 inches), with measuring capabilities from 0 to 2,200,000 kg/h (0 to 80,840 lb/min).
The device provides multivariable measurement, simultaneously capturing mass flow, density, temperature, volume flow, corrected volume flow, reference density, and concentration. Standard liquid mass flow accuracy is ±0.10%, with an optional PremiumCal upgrade to ±0.05%. Gas mass flow accuracy is ±0.25%, and liquid density accuracy is ±0.0005 g/cm³. The measuring principle requires no inlet or outlet straight pipe runs, enabling space-saving installation. Medium temperature range is –50 to +150°C as standard, with an optional high-temperature version extending to +240°C. Maximum process pressure reaches PN 100, Class 600, or 63K.
Wetted materials are extensively selected for durability and compatibility. Measuring tubes are available in 1.4539 (904L), 1.4404 (316/316L), and Alloy C22 (2.4602/UNS N06022). Process connections are available in 1.4404 (316/316L) and Alloy C22. The sensor housing is constructed of 1.4301/1.4307 (304L) stainless steel. The device holds material certificate 3.1 and is compliant with NACE MR0175/MR0103 standards. Hygienic approvals include 3-A, EHEDG, and cGMP.
The ultra-compact transmitter provides full functionality on the smallest footprint, ideal for space-constrained installations. Transmitter housing options include coated AlSi10Mg, 1.4301 (304), and 1.4404 (316L) stainless steel. The device is rated IP66/67, Type 4X enclosure, with an optional IP69 rating for demanding washdown environments. A 4-line backlit display is available for local operation, and configuration is accessible via an integrated web server without additional software or hardware. Digital communication options include HART, Modbus RS485, EtherNet/IP, PROFIBUS DP, and PROFINET. Power supply is DC 20 to 30 V.
Integrated Heartbeat Technology enables continuous process safety monitoring and traceable verification in accordance with ISO 9001:2015 (TÜV SÜD-attested) without process interruption, allowing extension of recalibration cycles. The device holds international hazardous area approvals including ATEX, IECEx, cCSAus, NEPSI, INMETRO, and EAC, with marine approvals from ABS, BV, LR, and CCS.
The Proline Promass F 100 delivers premium measurement performance for liquids and gases under varying, demanding process conditions, combining high accuracy, a robust ultra-compact design, multivariable measurement capability, and the diagnostic power of Heartbeat Technology.