BROWSE PRODUCTS

HIGH-QUALITY PROCESS CONTROL SOLUTIONS

Home > DCS > Yokogawa > Megger / Insulation Resistance Meter > Yokogawa Digital Insulation Tester MY10
  • Place of Origin: Japan
  • Brand Name: Yokogawa
  • Model Number: MY10
  • Product Name: Yokogawa Digital Insulation Tester MY10
  • Safety: good
  • Quality: International Standard for Yokogawa Digital Insulation Tester MY10
  • Accuracy: High Accuracy
  • Model: MY10

Yokogawa Insulation Tester MY10-01

Yokogawa Insulation Tester

Yokogawa Portable and Handheld Instrument

 

MY10 SERIES OF ANALOG TESTERS

Analog models with single rating

MY10-01:125V/20MΩ

MY10-02:250V/50MΩ

MY10-03:500V/100MΩ

MY10-04:500V/1000MΩ

MY10-05:1000V/2000MΩ

AC voltage measurement

Automatic discharge

A wide choice of accessories-Designed for shared use with the MY40

 

Specifications – Model MY10-01

Rating 125V/20MΩ
Effective Measuring Range 0.01-20MΩ
Central Scale Value 0.5MΩ
AC Voltage Measurement 0 to 250 V
Lower Limit 0.125MΩ
Rated Current 1-1.2 mA
Approx. Overall Scale Length 107 mm
Battery Life Approx. 10 hours when continuously operated on manganese – oxide batteries with the pointer pointing to the central scale value.
Batteries Four AA (R6P) batteries
Approx. Width 125 mm
Approx. Height 103 mm
Approx. Depth 53 mm
Approx. Weight 500 g
Compliance EN61010-1:1993; EN61010-2-31:1995 (Overvoltage Category III, Pollution Degree 2 installations for indoor use)
Standard Accessories Batteries (Qty – 4)
Earth Probe (98002) (Qty – 1)
Line Probe (98001) (Qty – 1)
Protection Cover (93013) (Qty – 1)
Shoulder Strap (99005) (Qty – 1)
User’s Manual (Qty – 1)

 

Standard Test Conditions – Model MY10-01

Ambient Temperature/Humidity Ranges 23 ±5 /45-75% RH
Position of Use Horizontal (5° max. of angle of inclination)
Battery Voltage Within effective voltage range (The pointer must stay within the range indicated by the BAT symbol when the battery check is performed.)
Tolerance Mentioned Conditions Resistance measurement: First effective measuring range = ±5% of reading
Second effective measuring range = ±10% of reading
Infinite and zero scale values: 0.7% max. of scale length
AC voltage: ±10% of maximum scale value
No-load voltage: 130% max. of rated voltage
Rated measuring current: 1 mA (0 to 20%) when in first effective measuring range
Short-circuit current: 12 mA max.

I am text block. Click edit button to change this text. Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.