All posts by conchgroup_admin

Endress Hauser Proline Prowirl F 200 Vortex Flow Meters

Vortex Flow Meters

Vortex Flow Meters Endress Hauser Proline Prowirl F 200 with detection of wet steam conditions, available as compact or remote version.

The Prowirl F measuring tube is the first choice in heavy duty applications. The proven and patented capacitive DSC sensor ensures high precision measured values even under the toughest process conditions. Prowirl F 200 offers wetsteam detection and industry-compliant two-wire technology for seamless integration into existing infrastructures and control systems, as well as high operational safety in hazardous areas thanks to an intrinsically safe design, and a familiar installation procedure.

Endress Hauser Proline Prowirl F 200 Vortex mass flowmeter

Application
• Preferred measuring principle for wet/saturated/ superheated steam, gases and liquids (also cryogenic)
• Suitable for a wide range of applications; optimized for steam applications

Device properties
• Wet steam detection and measurement for DN 25 to 100
• Inlet run compensation
• Face-to-face length according to industry standard
• Display module with data transfer function
• Robust dual-compartment housing
• Plant safety: worldwide approvals (SIL, Haz. area)

Your benefits
• Integrated temperature measurement for mass/energy flow of saturated steam
• Highest process safety – dualsens version enables redundant measurement
• High availability – proven robustness, resistance to vibrations, temperature shocks and water hammer
• No maintenance – lifetime calibration
• Convenient device wiring – separate connection compartment
• Safe operation – no need to open the device due to display with touch control, background lighting

Endress Hauser Proline Prowirl D 200 Vortex Flow Meters

Vortex Flow Meters

Vortex Flow Meters Endress Hauser Proline Prowirl D 200 is installed between flanges and mainly used for light duty applications.

The Prowirl D measuring tube is a disc/wafer model. The flowmeter is installed between flanges and mainly used for light duty applications. The proven and patented capacitive DSC sensor ensures high precision measured values. Prowirl D 200 offers industry-compliant two-wire technology for seamless integration into existing infrastructures and control systems, as well as high operational safety in hazardous areas thanks to an intrinsically safe design, and a familiar installation procedure.

Endress Hauser Proline Prowirl D 200 Vortex Flow Meters

Application
• Preferred measuring principle for wet/saturated/ superheated steam, gases & liquids (also cryogenic)
• For all basic applications and for 1-to-1 replacement of orifice plates

Device properties
• Face-to-face length of 65 mm (2.56 in)
• No flanges
• Low weight
• Display module with data transfer function
• Robust dual-compartment housing
• Plant safety: worldwide approvals (SIL, Haz. area)

Benefits

Built-in temperature measurement for saturated steam mass and energy flow measurements.
With central ring, sensor calibration easy
High Availability: good stability, high shock resistance, resistance to temperature shocks and water hammer
No maintenance: Calibration Lifecycle
Meter easy wiring, separate wiring compartment
Operational safety: a display module with touch keys, backlit display, without having to open the instrument operation
Built-in verification technology: Technology heartbeat

Your benefits
• Integrated temperature measurement for mass/energy flow of saturated steam
• Easy alignment of the sensor – included centering rings
• High availability – proven robustness, resistance to vibrations, temperature shocks & water hammer
• No maintenance – lifetime calibration
• Convenient device wiring – separate connection compartment
• Safe operation – no need to open the device due to display with touch control, background lighting
• Integrated verification – Heartbeat Technology™

Yokogawa GC1000 and GC8000 chromatography accessories

  • Place of Origin: Japan
  • Brand Name: Yokogawa
  • Model Number: GC1000 / GC8000
  • Product Name: Yokogawa GC1000 / GC8000 chromatography accessories
  • Safety: good
  • Quality: International Standard for Yokogawa chromatography accessories
  • Accuracy: High Accuracy
  • Model: GC1000 / GC8000

Analog input and output modules:
AAP149-S00 pulse input module is compatible with large-scale (16-channel, pulse count, 0-6 kHz, isolation)
AAI543-S00, AAI543-H00 analog output module (4-20 mA, 16-channel, isolated)
AAV142-S00 analog input module (-10 to + 10, 16 channels, isolated)
AAI841-S00, AAI841-H00 analog input / output modules (4-20 mA input, 4-20 mA output, 8 input / output channels, isolation)
AAB841-S00 analog input / output modules (1-5 volt input, 4-20 mA output, 8 input / output channels, isolation)
AAV542-S00 analog output module (-10 to + 10, 16 channels, isolated)
AAI143-S00, AAI143-H00 analog input module (4-20 mA, 16-channel, isolated)
AAV544-S00 analog output module (-10 to + 10, 16 channels, isolated)
AAI135-S00, AAI135-H00 analog input module (4-20 mA, 8-channel, isolated channel)
AAI835-S00, AAI835-H00 analog input / output modules (4-20 mA, 4-channel input / output channels, isolation channels)
AAT145-S00 millivolt input module (16 channels, isolated channel)
AAR145-S00 input modules (16 channels, isolated channel)
AAP135-S00 Pulse Input Module (8-channel, pulse count, 0-10 kHz channel isolation)
AAT141-S00 millivolt input module (16 channels, isolation)
AAR181-S00 resistance Input Module (12 channels, isolation)
AAP849-S00 pulse input module, analog output module (8 input / output channels, isolation)
AAI141-S00, AAI141-H00 analog input module (4-20 mA, 16-channel, isolated)
AAV141-S00 analog input module (1-5 volt, 16-channel, isolated)
AAV144-S00 analog input module (-10 to + 10, 16 channels, isolated)
Product Related Keywords: AAI835-H00 AAI835-H00 module AAI835-H00 input / output modules

Yokogawa T 101 Tonometer

  • Place of Origin: Japan
  • Brand Name: Yokogawa
  • Model Number: T-101
  • Product Name: Yokogawa T-101 Tonometer
  • Safety: good
  • Quality: International Standard for Yokogawa T-101 Tonometer
  • Accuracy: High Accuracy
  • Model: T-101

Model                                 Measuring range               Minimum scale

T-101-02-00                                0-0.2N                                  0.005N

T-101-05-00                                0-0.5N                                  0.01N

T-101-10-00                                0-1N                                     0.02N

T-101-20-00                                0-2N                                     0.05N

T-101-30-00                                0-3N                                     0.1N

T-101-50-00                                0-5N                                     0.1N

T-102-01-00                                0-10N                                   0.2N

T-102-02-00                                0-10N                                   0.5N

(gf)

T-101-02-10                                0-20gf                                 0.5gf

T-101-05-10                                0-50gf                                1.0gf

T-101-10-10                                0-100gf                              2.0gf

T-101-20-10                                0-200gf                              5.0gf

T-101-30-10                                0-300gf                             10.0gf

T-101-50-10                                0-500gf                             10.0gf

T-102-01-10                                0-1000gf                            20.0gf

T-102-02-10                                0-2000gf                             50.0gf

Yokogawa AAI835-H00 input and output modules

  • Place of Origin: Japan
  • Brand Name: Yokogawa
  • Model Number: AAI835-H00
  • Product Name: Yokogawa AAI835-H00 input / output modules
  • Safety: good
  • Quality: International Standard for Yokogawa AAI835-H00 input / output modules
  • Accuracy: High Accuracy
  • Model: AAI835-H00

Analog input and output modules:
AAP149-S00 pulse input module is compatible with large-scale (16-channel, pulse count, 0-6 kHz, isolation)
AAI543-S00, AAI543-H00 analog output module (4-20 mA, 16-channel, isolated)
AAV142-S00 analog input module (-10 to + 10, 16 channels, isolated)
AAI841-S00, AAI841-H00 analog input / output modules (4-20 mA input, 4-20 mA output, 8 input / output channels, isolation)
AAB841-S00 analog input / output modules (1-5 volt input, 4-20 mA output, 8 input / output channels, isolation)
AAV542-S00 analog output module (-10 to + 10, 16 channels, isolated)
AAI143-S00, AAI143-H00 analog input module (4-20 mA, 16-channel, isolated)
AAV544-S00 analog output module (-10 to + 10, 16 channels, isolated)
AAI135-S00, AAI135-H00 analog input module (4-20 mA, 8-channel, isolated channel)
AAI835-S00, AAI835-H00 analog input / output modules (4-20 mA, 4-channel input / output channels, isolation channels)
AAT145-S00 millivolt input module (16 channels, isolated channel)
AAR145-S00 input modules (16 channels, isolated channel)
AAP135-S00 Pulse Input Module (8-channel, pulse count, 0-10 kHz channel isolation)
AAT141-S00 millivolt input module (16 channels, isolation)
AAR181-S00 resistance Input Module (12 channels, isolation)
AAP849-S00 pulse input module, analog output module (8 input / output channels, isolation)
AAI141-S00, AAI141-H00 analog input module (4-20 mA, 16-channel, isolated)
AAV141-S00 analog input module (1-5 volt, 16-channel, isolated)
AAV144-S00 analog input module (-10 to + 10, 16 channels, isolated)
Product Related Keywords: AAI835-H00 AAI835-H00 module AAI835-H00 input / output modules

I am text block. Click edit button to change this text. Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.

Yokogawa CS1000 and CS3000 full range of battery

  • Place of Origin: Japan
  • Brand Name: Yokogawa
  • Model Number: CS1000/CS3000
  • Product Name: Yokogawa CS1000/CS3000 full range of battery
  • Safety: good
  • Quality: International Standard for Yokogawa CS1000/CS3000 battery
  • Accuracy: High Accuracy
  • Model: CS1000/CS3000

Yokogawa CS1000 / CS3000 system Battery Type:
S9581UK, S9325UK, S9583UK, S9072UD, S9080UK, S9766UK, S9628UK, S9322UK, S9559UK, S9415UK
S9400UK, S9129FA, S9765UK, S9528VK, S9762UK, S9767UK, S9763UK, S9490UF, S9578VK, S9504VK
S9764UK, S9039FA, S9027UV, S9879UK, S9502VK, S9580VK, S9504VK, S9506VK, S9579VK, S9109VK
Product Related Keywords: S9109VK S9109VK battery S9109VK Yokogawa battery

I am text block. Click edit button to change this text. Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.

Endress Hauser Proline Prowirl C 200 Vortex Flow Meters

Vortex Flow Meters

Vortex Flow Meters Endress Hauser Proline Prowirl C 200 is a product line of carbon steel vortex meters dedicated to the Canadian and American market.

  • Brand :Endress Hauser
  • Model:Endress Hauser Proline Prowirl C 200 Vortex Flow Meters
  • Diameter:DN 50 to 150 (2 to 6″)
  • Measurement error:Volume flow (liquid): ±0.75 %
    Volume flow (steam, gas): ±1.00 %
    Mass flow (liquid): ±0.85%
    Mass flow (steam, gas): ±1.7 %
  • Range: Liquid: 0.99 to 545 m³/h (0.58 to 321 ft³/min)
    depending on medium: water with 1 bar a, 20 °C (14.5 psi a, 68° F)
    Steam, gas: 13.8 to 7262 m³/h (8.12 to 4274 ft³/min)
    depending on medium: steam with 180 °C, 10 bar a (356 °F, 145 psi a); air with 25 °C, 4.4 bar a (77 °F, 63.8 psi a)
  • Output:4‐20 mA HART (passive)
    4‐20 mA (passive)
    Pulse/frequency/switch output (passive)
  • Input:4‐20 mA (passive)

Endress Hauser Proline Prowirl C 200 Vortex Flow Meters

Application
• Preferred measuring principle for wet/saturated/superheated steam, gases & liquids (also cryogenic)
• For steam applications with high chloride content (SAGD) aligned with AER Directive 017 Guidelines

Device properties
• Sensor made of carbon steel
• Material for low medium temperatures
• Display module with data transfer function
• Robust two-chamber housing
• Plant safety: CSA C/US and SIL approvals

Your benefits
• Compliance to AER – enables customer to fullfil inspection requirements
• Higher process control – unique inspection concept allows visual assessment of primary element
• High process safety – resistant to inter-granular stress corrosion cracking
• Convenient device wiring – separate connection compartment
• Safe operation – no need to open the device due to display with touch control, background lighting
• Integrated verification – Heartbeat Technology™

Yokogawa ZR402G converter

  • Place of Origin: Japan
  • Brand Name: Yokogawa
  • Model Number: ZR402G
  • Product Name: Yokogawa ZR402G converter
  • Safety: good
  • Quality: International Standard for Yokogawa ZR402G converter
  • Accuracy: High Accuracy
  • Model: ZR402G

Yokogawa ZR402G Separate type Humidity Analyzer Averaging Converter

ZR402G Yokogawa Humidity Analyzer Averaging Converter works with separate type detector ZR22G or ZR22S, which output 4 to 20 mA DC signal. It use LCD touch screen interface, display Value, Graph, Data, Status, Alarm and Errors on time.  Moreover, it owns automation calibration , Blow back and Self-diagnosis functions.

 

ZR402G Yokogawa Humidity Analyzer Averaging Converter owns below typical features:

1. Liquid-crystal touch panel display provides easy operation.
2. Interactive operations along with operation display.

3. Back-lit LCD allows viewing even in the darkness

4. Digital communications enables to be maintenance serviced remotely.

5. Can measure either oxygen concentration or humidity with a single analyzer.

6. Highly reliable measurements with trend-data graphs

7. Error codes and details of errors can be checked in the field without the need to refer to the appropriate instruction manual.

Yokogawa ZR22G Zirconia oxygen analyzer

  • Place of Origin: Japan
  • Brand Name: Yokogawa
  • Model Number: ZR22G
  • Product Name: Yokogawa ZR22G Zirconia oxygen analyzer
  • Safety: good
  • Quality: International Standard for Yokogawa ZR22G Zirconia oxygen analyzer
  • Accuracy: High Accuracy
  • Model: ZR22G

Yokogawa ZR22G Separate type Zirconia Oxygen Analyzer O2 Analyzer

ZR22G Yokogawa O2 Analyzer is EXAxt series ZR Separate type Zirconia Oxygen/Humidity Analyzer which usually work with connected ZR402G or AV550G converter. It is used or combustion monitoring and control in a wide variety of applications and help industries to make considerable achievements in energy saving such as iron and steel, electric power, oil and petrochemical, ceramics, pulp and paper, food, and textiles, also to various combustion facilities, such as incinerators and small- and medium sized boilers. Combustion monitoring and control using the analyzer also contribute to a lowering of CO2, SOx, and NOx emissions by allowing for more complete combustion, thus preventing global warming and air pollution.

Yokogawa ZR22G O2 Analyzer owns below typical features:

1. The built-in heater assembly of the probe can be replaced on site, reducing maintenance costs
2. The probe uses a long-life, high-reliability Zirconia sensor
3. The probe uses three-reference gas supply methods for compensation in applications
4. Remote maintenance using digital communications(HART) reduces maintenance costs
5. Wide range of wetted part material optional, SUS 316 (JIS), Hastelloy, Inconel

 

ZR22G SPECIFICATION
Measurement object
 Oxygen concentration in combustion exhaust gas and mixed gas
Measurement system
 Zirconia system
Measurement range
0.01 to 100 vol%O2
Output signal
4 to 20 mA DC, two points (maximum load resistance 550 Ω)
Setting range
Any setting in the range of 0 – 5 vol%O2 to 0 – 100 vol%O2 (in 1 vol%O2), or partial range
Digital communication (HART)
250 to 550 Ω, depending on number of field devices connected to the loop (multi-drop mode)
Sample gas pressure
-5 to +250 kPa
Sample gas temperature
0 to 700℃ (Probe only)
700 to 1400℃ (with 0.15m probe and High Temperature Probe Adapter)
Probe length
 0.15, 0.4, 0.7, 1.0, 1.5, 2.0, 2.5, 3.0, 3.6,4.2, 4.8, 5.4 m
Contact output
Four points (one is fail-safe, normally open)
Contact input
Two points
Calibration
Method ; zero/span calibration
Calibration mode ;
automatic, semi-automatic and manual (All are operated interactively with an LCD touchscreen)
Construction of detector
Heater and thermocouple replaceable construction.
Non-explosion-proof. Equivalent to NEMA4X/IP66
Converter Construction
Outdoor installation. Equivalent to NEMA4X/IP66
Ambient temperature
Probe: -20 to 150℃, Converter: -20 to 55℃
Power supply
 85 to 264 V AC; 45 to 66 Hz

Yokogawa ZR202G Zirconia oxygen analyzer

  • Place of Origin: Japan
  • Brand Name: Yokogawa
  • Model Number: ZR202G
  • Product Name: Yokogawa ZR202G Zirconia oxygen analyzer
  • Safety: good
  • Quality: International Standard for Yokogawa ZR202G Zirconia oxygen analyzer
  • Accuracy: High Accuracy
  • Model: ZR202G

Yokogawa ZR202G Integrated type Explosion-proof Zirconia Oxygen Analyzer O2 Analyzer

ZR202G Yokogawa O2 Analyzer is EXAxt series ZR Integrated type Zirconia Oxygen/Humidity Analyzer which usually used or combustion monitoring and control in a wide variety of applications and help industries to make considerable achievements in energy saving such as iron and steel, electric power, oil and petrochemical, ceramics, pulp and paper, food, and textiles, also to various combustion facilities, such as incinerators and small- and medium sized boilers. Combustion monitoring and control using the analyzer also contribute to a lowering of CO2, SOx, and NOx emissions by allowing for more complete combustion, thus preventing global warming and air pollution.
ZR202G Yokogawa O2 Analyzer is normally for monitoring the oxygen concentration or achieving low oxygen combustion in large- or small-sized boilers, various industrial furnaces, and combustion equipment.

ZR202G Yokogawa O2 Analyzer owns below typical features:

1. The built-in heater assembly of the probe can be replaced on site, reducing maintenance costs
2. The probe uses a long-life, high-reliability Zirconia sensor
3. Remote maintenance using digital communications(HART) reduces maintenance costs
4. Wide range of wetted part material optional, SUS 316 (JIS), Hastelloy, Inconel
5. Integrate both probe and converter, to reduce wiring, piping, installation costs.
6. Measure either oxygen concentration or humidity
7. Infrared switch operation

ZR202G SPECIFICATION
Measurement object
 Oxygen concentration in combustion exhaust gas and mixed gas
Measurement system
 Zirconia system
Display
6-digit LCD
Switch
Three optical switches
Measurement range
0.01 to 100 vol%O2
Output signal
4 to 20 mA DC, two points (maximum load resistance 550 Ω)
Setting range
Any setting in the range of 0 – 5 vol%O2 to 0 – 100 vol%O2 (in 1 vol%O2), or partial range
Digital communication (HART)
250 to 550 Ω, depending on number of field devices connected to the loop (multi-drop mode)
Sample gas pressure
-5 to +250 kPa
Sample gas temperature
0 to 700℃ (Probe only)
700 to 1400℃ (with 0.15m probe and High Temperature Probe Adapter)
Probe length
0.4, 0.7, 1.0, 1.5, 2.0, 2.5, 3.0 m
Contact output
Four points (one is fail-safe, normally open)
Contact input
Two points
Calibration
Method ; zero/span calibration
Calibration mode ;automatic, semi-automatic and manual (with optical switch)
Construction of detector
Heater and thermocouple replaceable construction.
Non-explosion-proof. Equivalent to NEMA4X/IP66
Converter Construction
Outdoor installation. Equivalent to NEMA4X/IP66
Ambient temperature
 -20 to 55℃
Power supply
 85 to 264 V AC; 45 to 66 Hz

Yokogawa ZR22S Zirconia oxygen analyzer

  • Place of Origin: Japan
  • Brand Name: Yokogawa
  • Model Number: ZR22S
  • Product Name: Yokogawa ZR22S Zirconia oxygen analyzer
  • Safety: good
  • Quality: International Standard for Yokogawa ZR22S Zirconia oxygen analyzer
  • Accuracy: High Accuracy
  • Model: ZR22S

Top selling Yokogawa ZR22S Integrated type Explosion-proof Zirconia Oxygen Analyzer

ZR22S Yokogawa zirconia oxygen analyzer is EXAxt series ZR Separate type Zirconia Oxygen/Humidity Analyzer which usually work with connected ZR402G or AV550G converter. It does not need a sampling device, and allow direct installation of the probe in the wall of a flue or furnace to measure the concentration of oxygen in the stack gas. The converter displays the cell temperature and cell emf in addition to the oxygen concentration.

ZR22S Yokogawa zirconia oxygen analyzer is most suitable for monitoring combustion and controlling the low-oxygen combustion of various industrial furnaces in explosive atmospheres at petroleum refineries, petrochemical plants, and natural gas plants.

ZR22S Yokogawa zirconia oxygen analyzer owns below typical features:

1. The built-in heater assembly of the probe can be replaced on site, reducing maintenance costs
2. The probe uses a long-life, high-reliability Zirconia sensor
3. The probe uses three-reference gas supply methods for compensation in applications
4. Remote maintenance using digital communications(HART) reduces maintenance costs
5. Wide range of wetted part material optional, SUS 316 (JIS), Hastelloy, Inconel
6. Explosion-proof design

 

ZR22S SPECIFICATION
Measurement object
 Oxygen concentration in combustion exhaust gas and mixed gas
Measurement system
 Zirconia system
Explosion-proof Approval
ZR22S-A (ATEX); EEx d IIB + H2,
ZR22S-B (FM); Class I, Division1, Groups B, C and D
ZR22S-C (CSA); Class I, Division1, Groups B, C and D
ZR22S-D (IECEx); Ex d IIB + H2, T2
Measurement range
0.01 to 100 vol%O2
Output signal
4 to 20 mA DC, two points (maximum load resistance 550 Ω)
Setting range
Any setting in the range of 0 – 5 vol%O2 to 0 – 100 vol%O2 (in 1 vol%O2), or partial range
Digital communication (HART)
250 to 550 Ω, depending on number of field devices connected to the loop (multi-drop mode)
Sample gas pressure
-5 to +5 kPa
Sample gas temperature
0 to 700℃ (Probe only)
700 to 1400℃ (with 0.15m probe and High Temperature Probe Adapter)
Probe length
0.15, 0.4, 0.7, 1.0, 1.5, 2.0 m
Contact output
Four points (one is fail-safe, normally open)
Contact input
Two points
Calibration
Method ; zero/span calibration
Calibration mode ;
automatic, semi-automatic and manual (All are operated interactively with an LCD touchscreen)
Construction of detector
Heater and thermocouple replaceable construction, equivalent to NEMA4X/IP66
Converter Construction
Outdoor installation. Equivalent to NEMA4X/IP66
Ambient temperature
Terminal box: -20 to 60℃, Converter: -20 to 55℃
Reference Gas System
Instrument Air; 50 kPa
Wiring Connection
ATEX; M20 by 1.5 mm or 1/2 NPT select one type (4 pieces)
FM; 1/2 NPT (4 pieces)
CSA; 1/2 NPT (4 pieces)
IECEx; M20 by 1.5 mm or 1/2 NPT select one type (4 pieces)
Power supply
 85 to 264 V AC; 45 to 66 Hz

 

Yokogawa E7042UD zirconium pool

  • Place of Origin: Japan
  • Brand Name: Yokogawa
  • Model Number: E7042UD
  • Product Name: Yokogawa E7042UD zirconium pool
  • Accuracy: High
  • Safety: Good
  • Quality: International Standard for Yokogawa E7042UD zirconium pool

 

E7042UD  zirconium pool
E7042UD, E7046EC, E7046EN Yokogawa zirconium can be used to split pool zirconia analyzer ZR22G / ZR22S and integrated type Zirconia analyzer ZR202G.
E7042UD, E7046EC, E7046EN zirconia conductivity cell and the heater can be conveniently replaced in the field the improved operator panel · interactive and safe.
E7042UD zirconia cell Product Description:
Yokogawa’s zirconia oxygen analyzer is widely used in the combustion process monitoring and control a variety of industries.

 

It helps in the areas of industrial energy-saving industries including energy-intensive industries, such as iron and steel industry, power electronics, petrochemicals, ceramics, paper industry, food industry, textile industry, but also includes a variety of combustion devices such as incinerators , small and medium sized boilers. This analyzer used in combustion monitoring and control, will contribute to the full combustion, reducing CO2, CO, SOx and NOx emissions, so as to prevent global warming and contribute to air pollution. Features * LCD touch screen can be easy to operate

  • Interactive navigation operation. Display setting information, and the oxygen concentration curve correction information (optional)
  • You can measure oxygen concentration and humidity
  • Chart curve data show highly credible measurement information

Product Related Keywords: E7046EN E7046EN zirconium zirconia cell pool E7046EN