Electromagnetic Flowmeter
Electromagnetic Flowmeter Endress Hauser Proline Promag 50E offers accurate measurement of liquids for a wide range of standard applications.
- Brand :Endress Hauser
- Model:Endress Hauser Electromagnetic Flowmeter Proline Promag 50E
- Diameter:DN 15 to 600 (½ to 24″)
- Measurement error:Volume flow (standard): ±0.5 % o.r. ± 1 mm/s (0.04 in/s)
Volume flow (option): ±0.2 % o.r. ± 2 mm/s (0.08 in/s) - Range:4 dm³/min to 9600 m³/h (1 to 44 000 gal/min)
- Pressure range: PN 40, Class 150, 20K
- Process Temperature: –10 to +110 °C (+14 to +230 °F)
- Output: 3 outputs:
0‐20 mA (active)/4‐20 mA (active/passive)
Pulse/frequency output (passive)
Switch output (passive) - Input:Status input
Endress Hauser Electromagnetic Flowmeter Proline Promag 50E
Application
• The measuring principle is virtually independent of pressure, density, temperature and viscosity
• Fully suitable for basic applications in the chemical and process industry
Device properties
• Nominal diameter: max. DN 600 (24″)
• Ex approvals for Zone 2
• Liner made of PTFE
• 2-line backlit display with push buttons
• Device in compact or remote version
• HART, PROFIBUS DP/PA
Your benefits
• Cost-effective sensor – ideal solution for basic requirements
• Energy-saving flow measurement – no pressure loss due to cross-section constriction
• Maintenance-free – no moving parts
• Fast commissioning – application-specific Quick Setups
• Safe operation – display provides easy readable process information
• Fully industry compliant – IEC/EN/NAMUR