BROWSE PRODUCTS

HIGH-QUALITY PROCESS CONTROL SOLUTIONS

Home > Transmitters > Rosemount > Rosemount 2090P Pulp and Paper Pressure Transmitter
Rosemount 2090P Pulp and Paper Pressure Transmitter

Rosemount Pressure Transmitter

Rosemount 2090P Pulp and Paper Pressure Transmitter

The 2090P can be calibrated to ranges as low as 0 to 1.5 psi (0.1 bar) and as high as 0 to 300 psi (20.7 bar). The combination of these superior measurement capabilities, its compact size and rugged construction make it ideal for pulp and paper applications.

  • Reference Accuracy: ± 0.20% of span
  • Rangeability: 20:1
  • Installed Stability of ± 0.10% of URL for 12 months
  • Available in 4-20mA HART® protocol
  • Available in 1-inch flush mount compatible with a PMC® process connection, or 1½-in. threaded mounting connection

Rosemount Pressure Transmitter

Rosemount 2090P Pulp and Paper Pressure Transmitter

The 2090P has process connections that position the

isolation diaphragm flush with vessel or pipe walls,

eliminating clogging problems associated with highly viscous

processes that tend to crystallize, polymerize, or

precipitate, such as those in the pulp and paper industry.

Absolute or gauge pressure ranges up to 300 psi and 20:1

turndown

Higher turndown allows for lower inventories by allowing you

to measure pressures from 1.5 psi to 300 psi with only three

transmitter ranges.

Communicates via the HART protocol

The 2090P utilizes the advantages of HART communication,

enabling quick and easy reranging, calibration and

troubleshooting.

0.20% reference accuracy including linearity, hysteresis, and

repeatability

The single-filled sensor system of the 2090P leads to

outstanding accuracy due to full sensor compensation.

1-in. flush mount compatible with PMC process connection,or

1 1/2-in. threaded mounting connection

The 2090P has process connections that position the

isolation diaphragm flush with vessel or pipe walls,

eliminating clogging problems associated with highly viscous

processes that tend to crystallize, polymerize, or

precipitate, such as those in the pulp and paper industry.

Absolute or gauge pressure ranges up to 300 psi and 20:1 turndown

Higher turndown allows for lower inventories by allowing you

to measure pressures from 1.5 psi to 300 psi with only three

transmitter ranges.

Communicates via the HART protocol

The 2090P utilizes the advantages of HART

communication,enabling quick and easy reranging, calibration

and troubleshooting.