Yokogawa EJA210E Flange Mounted Differential Pressure Transmitter

Yokogawa Flange Mounted Differential Pressure Transmitter

Yokogawa EJA210E Flange Mounted Differential Pressure Transmitter

The EJA-E series of transmitters is Yokogawa’s most recent evolution of the DPharp family. Released in 2012, it combines the ruggedness and success of the work-horse.

EJA-A series with the performance of the thoroughbred EJX-A series to deliver the type of product you have come to expect from Yokogawa.

The high performance differential pressure transmitter EJA210E can be used to measure levels of densities of solidifying or precipitating liquids.

  • For 4 to 20 mA HART / BRAIN
    (Output signal code D and J)
  • Update Period :Differential pressure: 45 ms
    Static pressure: 360 ms
  • Accuracy
    Absolute Pressure
    1 MPa or higher: ±0.5% of span
    Less than 1 MPa: ±0.5%×(1 MPa/span) of span
    Gauge Pressure Reference
    Gauge pressure reference is 1013 hPa (1 atm)

Yokogawa  Flange Mounted Differential Pressure Transmitter

Yokogawa EJA210E Flange Mounted Differential Pressure Transmitter

The high performance flange mounted differential
pressure transmitter EJA210E can be used  to measure levels of densities of solidifying or precipitating liquids.

Meanwhile, It also features quick response, remote setup and monitoring via BRAIN or HART communications and self-diagnostics.

Stability:±0.1 % of URL per 12 months
Power Supply Effects(Output signal code D and J)
±0.005 % per Volt (from 21.6 to 32 V DC, 350Ω)
Response Time (Differential pressure)
M and H capsule: 120 ms (approximate value at normal temperature)
When software damping is set to zero and including
dead time of 45 ms (nominal)

Load for 4 to20 mA HART/BRAIN(Output signal code D and J)
0 to 1290Ω for operation
250 to 600Ω for digital communication

Output Load for 1 to 5 V HART (Output signal code Q)
1 MΩ or greater (meter input impedance)
Note that with three-wire connection, the cable length
may affect the measurement accuracy of the output
signal.