BROWSE PRODUCTS

HIGH-QUALITY PROCESS CONTROL SOLUTIONS

Home > Transmitters > Yokogawa > EJA series > Yokogawa EJA510A -DD Absolute Pressure Transmitter
Yokogawa EJA510A -DD Absolute Pressure Transmitter

Yokogawa EJA510A -DD Absolute Pressure Transmitter

The absolute pressure transmitter model EJA510A can be used to measure liquid, gas, or steam pressure.

Ambient Temperature Effects

Total Effects per 28 °C (50 °F) Change

±[0.15% Span + 0.15% URL]

Stability

±0.1% of URL per 12 months

Power Supply Effects “◊

±0.005 % per Volt (from 21.6 to 32 V DC, 350 )

Output “◊

Two wire 4 to 20 mA DC output with digital communi-cations. BRAIN or HART FSK protocol are superim-posed on the 4 to 20 mA signal.

Weight

1.6 kg (3.5 lb) without integral indicator, mounting bracket.

Failure Alarm

Output status at CPU failure and hardware error;

Up-scale: 110%, 21.6 mA DC or more (standard)

Down-scale: -5%, 3.2 mA DC or less

-2.5%, 3.6 mA DC or less (Optional

code /F1)

Note : Applicable for Output signal code D and E.

Description

Ambient Temperature Limits

(approval codes may affect limits)

-40 to 85 °C (-40 to 185 °F)

-30 to 80 °C (-22 to 176 °F) with LCD Display

Process Temperature Limits

(approval codes may affect limits)

-40 to 120 °C (-40 to 248 °F)

Ambient Humidity Limits

5 to 100 % RH @ 40 °C (104 °F)