Electromagnetic Flowmeter
Electromagnetic Flowmeter Endress Hauser Proline Promag 50L offers highly accurate measurement of liquids for a wide range of standard applications.
- Brand :Endress Hauser
- Model: Endress Hauser Electromagnetic Flowmeter Proline Promag 50L
- Diameter:Lap joint flange; lap joint flange, stamped plate: DN 25 to 300 (1 to 12″)
Fixed flange: DN 350 to 2400 (14 to 90″) - Measurement error:Volume flow (standard): ±0.5 % o.r. ± 1 mm/s (0.04 in/s)
Volume flow (option): ±0.2 % o.r. ± 2 mm/s (0.08 in/s) - Range:9 dm³/min to 162 000 m³/h (2.5 gal/min to 1030 Mgal/d)
- Pressure range: PN 16, Class 150
- Process Temperature:Liner material hard rubber: 0 to +80 °C (+32 to +176 °F)
Liner material polyurethane: –20 to +50 °C (–4 to +122 °F)
Liner material PTFE: –20 to +90 °C (–4 to +194 °F) - Output: 3 outputs:
0‐20 mA (active)/4‐20 mA (active/passive)
Pulse/frequency output (passive)
Switch output (passive) - Input:Status input
Endress Hauser Electromagnetic Flowmeter Proline Promag 50LH
Application
• The measuring principle is virtually independent of pressure, density, temperature and viscosity
• Fully suitable for standard applications in the water and wastewater industry
Device properties
• Up to 30 % less sensor weight
• Nominal diameter: DN 25 to 2400 (1 to 90″)
• Maximum reduced installation length to DVGW/ISO
• 2-line backlit display with push buttons
• Device in compact or remote version
• HART, PROFIBUS PA/DP
Your benefits
• Reduced installation costs – flexible mounting by one-of-akind lap-joint flange concept (DN < 350/14″)
• Energy-saving flow measurement – no pressure loss due to cross-section constriction
• Maintenance-free – no moving parts
• Fast commissioning – application-specific Quick Setups
• Safe operation – display provides easy readable process information
• Fully industry compliant – IEC/EN/NAMUR