Yokogawa TY530 Multimeter

  • Place of Origin: Japan
  • Brand Name: Yokogawa
  • Model Number: TY530
  • Product Name: Yokogawa TY530 Multimeter
  • Safety: good
  • Quality: International Standard for Yokogawa TY530 Multimeter
  • Accuracy: High Accuracy
  • Model: TY530

Yokogawa TY530 Multimeter

 

3.5-digit (6000-count dual display, 31-segment bar graph display), RMS type Measurement Functions : Voltage, Current, Resistance, Continuity Check, Diode Test, Frequency, Capacitance, Temperature, Logging-mode memory for 1600 data (TY530 only)

 

Features : Category IV 600V, Category III 1000V, USB Communication function, Closed Case Calibration (User calibration function).

 

Measurement Function DC Voltage, AC voltage, DC current, AC current, resistance, frequency, temperature, capacitance, continuity check, diode test For AC voltage/current, RMS/MEAN detection can be switched.
Low-pass filter can be switched on/off
Additional Functions Data hold/auto hold/range hold, maximum/minimum/average values, resistance, relative and percentage value calculation, memory function, communication function, logging-mode memory, auto power off, backlight
Display 3.5-digit LCD: 7-segment
Digital display: Main display; [6000] counts
Bar graph display: 31-segment
Polarity indicator : “-” appears automatically when the polarity is negative
Overrange indicator: “OL”
Features
  • High Precision
  • Basic accuracy 0.09%
  • True RMS measurement
  • Ensured Field Site Safety
  • Conforms to safety standards EN61010-1, 1000V CAT III, 600V CAT IV
  • Safety shutters for preventing erroneous insertion of test leads into current measurement terminals
  • New Functions for Yokogawa Middle Class DMMs
  • Current direct reading function provided by current clamp sensor (optional)
  • Low-pass Filter (LPF)
  • Logging-mode memory for 1600 data
  • USB communication, application software (Optional DMM communication package) TY530 only
  • Closed Case Calibration
  • 3-year Warranty

 

Yokogawa 322610 Leakage current tester

  • Place of Origin: Japan
  • Brand Name: Yokogawa
  • Model Number: 322610
  • Product Name: Yokogawa 322610 Leakage current tester
  • Safety: good
  • Quality: International Standard for Yokogawa 322610 Leakage current tester
  • Accuracy: High Accuracy
  • Model: 322610

Features:

  • Three input resistance ranges – 1,1.5 and 2 kΩ
  • Four functions – AC current, DC current. DC + AC current and AC voltage measurements
  • ± 2.5% full scale accuracy
  • 100μA full scale value
  • Shockproof indicator using taut band movement
  • Built-in overload protection circuit
  • Handy and easy to carry
  • Shielded case, resistant to high-frequency fields

Examples of Application Areas:

  • Electrothermal appliances
    Room heating (electric stove), cooking (toaster), hair-dressing (electric curling iron, hair dryer and curlers).
  • Motor operated appliances
    electric fan, floor polisher, washing machine, electrical pump, refrigerator, electric drill, vending machine, lawn mower and electrical toys.
  • Light source appliances
    Duplicator, projector, photographic enlarger, and electrical disinfector.
  • Electronic appliances
    TV receiver, microwave ranges, and high-frequency welding machine.
  • Other appliances
    Burglar alarm, medical and dental equipment, noise suppressor, and portable generator.

Specifications

Ranges

DC current – 0.1, 1. 10mA, AC current – 0.1, 1, 10mA, (DC + AC) current – 0.1, 1, 10mA, AC Voltage – 150, 300V (50 and 60 Hz)

Accuracy

±2.5% of full scale value on current and voltage range

Input Impedance

Current range: 1kΩ 1.5kΩ , and 2kΩ Voltage range; More than 100kΩ

Frequency Range

20 Hz to 5 kHz

Power Source

Two 9V dry cells (JIS C8501 Type 006P or NEDA 6F22), Continuous Operating Time; Approx. 290 hours

Overload Protection

Up to 30mA AC for one minute will not damage instrument oh current ranges

Temperature Influence

±0.2% of rated value/°C against temperature variation of 20± 10°C

Insulation Resistance

More than 20 MΩ at 500 V DC between terminals and case

Dielectric Strength

1500V AC 50Hz for one minute between electrical circuit and case

Dimensions

Approx. 190 x 124 x 90 mm (7.48 x 4.88 x 3.54″) not including handle

Weight

Approx. 1.0 kg (2.2 lbs)

Accessories1

Carrying Case (322400) 1 pc Carrying Case (B9646BU) 1 pc Instruction Manual 1 copy Test Lead (289803) 1 pc. Test Lead (B9646CM) 1 pc.

Optional Accessories

322710 Text Box

 

Yokogawa CA11E Calibrator

  • Place of Origin: Japan
  • Brand Name: YOKOGAWA
  • Model Number: CA11E
  • Product Name: Yokogawa CA11E Calibrator
  • Model: CA11E
  • Output: 4-20MA
  • Safety: Safety
  • Quality: International Standard for Yokogawa CA11E Calibrator

CA11E Features:
Generate and measure the voltage and current signals
It can generate and measure the maximum 30V DC voltage and maximum current of 24mA DC.

 

Improved current display resolution

Generation / measurement resolution to 0.001mA.

 

24V (20mA) / loop check function

Able to measure generated current signals while to loop powered two-wire transmitter. Current load: DC 22A

 

20mA SINK function
Absorbed from the external power supply to its H terminal of the supply voltage, and analog two-wire transmitter, ideal for loop checks.

 

4-20mA and 1-5V DC step up / drop function
For 4-20mA DC output, click the button to change the output signal level between 4-8-12-16-20mA for 1-5V DC output, click the button to the 1-2-3-4- change between 5V signal output level, allowing efficient calibration.

 

Scan function
In the selected scan time (16 seconds or 32 seconds), at a constant rate will increase or decrease the output level to a preset level. Scan function switch settings and scanning time by internal DIP.
CA11E voltage calibrator – Current Calibrator

 

  • Source: DCV (maximum 30V), DCA (maximum 24mA)
  • Measurement: DCV (maximum 30V), DCA (maximum 100mA)
  • Features: Automatic stepping (4 ~ 20mA), 20mA SINK, sleep function
  • Option: CA11E-2 contains a rubber sleeve, straps and accessory box

Specifications:

Features

Simulator of Common Thermocouples and RTD Sensors Outputs a signal equivalent to signals of ten types of thermocouple K, E, J, T, N, S, B, L, M and R as well as Pt100 esistance temperature detector.Suitable for a broad range of applications such as maintenance of industrial process instruments and various thermometers. Multi-range Thermometer Can be used as a multi-range thermometer. Three-wire RTD connection for an RTD is possible. Built-in Sensor for Reference Junction Compensation Reference junction compensation when generating a thermocouple signal can be performed by the built-in temperature sensor. For more precise compensation, use the external RJC sensor (model B9108WA, sold separately). Shift Key Selects temperature” or RTD” unit. Terminal Adapter Provides screw terminals for connecting a temperature sensor such as a thermocouple and RTD when measuring temperature. When generating an RTD signal, a three-wire RTD signal can be output using the lead cables that come with the CA12E by short-circuiting the Lo-Lo terminals using the short-circuit bar that also comes with the CA12E. Plug for External RJC Sensor The RJC sensor is sold separately. Plug for AC Adapter Common for all CA11E, CA12E

Standard Accessories

Carrying Case

Power Supply

Four 1.5-V alkaline batteries (ANSI AA-size) or dedicated AC adapter (sold separately)

Battery Life

Approx. 55 hours When generating a signal continuously on alkaline batteries

Automatic Power-Off

Approx. 10 minutes (Can be canceled by DIP switch setting)

Generation Signal Level Setting

By four-digit up/down keys

Response of Generator

400? and RTD range : Approx. 20 milliseconds (from when the specified current is applied until when the output level falls within the specified accuracy)

Applied Voltage

42 V peak or less between each terminal and ground

Measurement Display

Approx. 1 update/sec.

Update interval Display

7 segments LCD

Operating Temperature/Humidity Range

0 to 50°C and 20 to 85%RH (no condensation)

Storage Temperature/Humidity Range

-20 to 50°C and 90%RH or less (no condensation)

Dimensions

Approx. 192 (W) x 92 (H) x 42 x (D) mm (Excluding protrusions)

Width

192 mm

Height

92 mm

Thickness

42 mm

Weight

Approx. 440 g (including batteries)

Additional Features

Automatic Power-off Choose either “rubber boot” or “carrying case” Compact and Lightweight Complete Protection (CA11E) Dip Switches (inside battery compartment) Longer Lead Cables Runs on 1.5 V AA-size Batteries or AC Adapter Simple and Easy Calibration

 

Honeywell Low thermal resistance terminal board MC-TAMR03

Honeywell MC-TAMR03

Honeywell MC-TAMR03 51305907-175 FTA, LLMUX2, RTD, CE, CC

Professional to provide a Honeywell DCS card, integrity services, absolute guarantee is part of the original Honeywell new card, the scope of services involved S9000, plantscape, TDC2000 TDC3000 (US operation station), TPS (Gus operation station), PKS and Honeywell DCS distributed control system

Honeywell Low thermal resistance terminal board MC-TAMR03

51305896-200 51401473-100 51309288-375 REV.K-TK-PRR021 51192337-100
CC-TAIX11 redundancy HLAI IO terminal board
CC-PWRB01 redundant DC power module 20A
CC-PAIM01LLMUX module 64 channels
CC-PDOB01DO module 32 channels
CC-PDIS01DI SOE module features 32 channels
CC-PDIL01DI module 32 channels
CC-PAOX01AO module does not support the Hart protocol
CC-PAOH01AO Hart protocol module supports 16 channels
CC-PAIX01HLAI module does not support the Hart protocol 16 channels
CC-PAIH01HLAI Hart protocol module supports 16 channels
CC-TCNT01C301 controller backplane
CC-PCNT01C300 Controller
CC-TCF901 control firewall floor
CC-PAOH01 51405039-175
CC-PDIL01 51405040-175
CC-PDOB01 51405043-175
CC-PCF901 control firewall
TP-OPADP1-201
51401052-100
51400646-100
51309276-150
51308092-200
51308035-100
51305907-175 (MC-TAMR04) 51305896-200
51305890-175 (MC-TAMT04) 51305380-100
51305348-100 (HI-ZUG100) 51305378-100
51304913-100
51304754-150 (MC-PAIH03)

  • 9904-TPR ControlNet T Tap right angle 4
  • TC-CCN013 CNI Module, Single Media 1
  • TC-CCR013 CNI Module, Redundant Media 2
  • TC-FFPCX1 Power Supply Module, 1.3 A, RIOM-A 1
  • TC-FPCXX2 120 / 240vac Pwr Supply 1
  • TC-FPDXX2 24Vvdc Pwr Supply 0
  • TC-FXX102 10 Slot Chassis, 13 Amp 2
  • TC-FXX132 13 Slot Chassis, 13 Amp 2
  • TC-IAH061 Analog Input 8px Module, CIOM-A 1
  • TC-IAH161 AI 16 Module (single8 diff.), CIOM-A 0

There are a lot of models do not have the statistics, if you need, please contact me or send e-mail and phone

Yokogawa CA12E Calibrator

  • Place of Origin: Japan
  • Brand Name: YOKOGAWA
  • Model Number: CA12 E
  • Product Name: Yokogawa CA12 E Calibrator
  • Model: CA12 E
  • Output: 4-20MA
  • Safety: Safety
  • Quality: International Standard for Yokogawa CA12 E Calibrator

CA11E Features:
Generate and measure the voltage and current signals
It can generate and measure the maximum 30V DC voltage and maximum current of 24mA DC.

 

Improved current display resolution

Generation / measurement resolution to 0.001mA.

 

24V (20mA) / loop check function

Able to measure generated current signals while to loop powered two-wire transmitter. Current load: DC 22A

 

20mA SINK function
Absorbed from the external power supply to its H terminal of the supply voltage, and analog two-wire transmitter, ideal for loop checks.

 

4-20mA and 1-5V DC step up / drop function
For 4-20mA DC output, click the button to change the output signal level between 4-8-12-16-20mA for 1-5V DC output, click the button to the 1-2-3-4- change between 5V signal output level, allowing efficient calibration.

 

Scan function
In the selected scan time (16 seconds or 32 seconds), at a constant rate will increase or decrease the output level to a preset level. Scan function switch settings and scanning time by internal DIP.
CA11E voltage calibrator – Current Calibrator

 

  • Source: DCV (maximum 30V), DCA (maximum 24mA)
  • Measurement: DCV (maximum 30V), DCA (maximum 100mA)
  • Features: Automatic stepping (4 ~ 20mA), 20mA SINK, sleep function
  • Option: CA11E-2 contains a rubber sleeve, straps and accessory box

Specifications:

Features

Simulator of Common Thermocouples and RTD Sensors Outputs a signal equivalent to signals of ten types of thermocouple K, E, J, T, N, S, B, L, M and R as well as Pt100 esistance temperature detector.Suitable for a broad range of applications such as maintenance of industrial process instruments and various thermometers. Multi-range Thermometer Can be used as a multi-range thermometer. Three-wire RTD connection for an RTD is possible. Built-in Sensor for Reference Junction Compensation Reference junction compensation when generating a thermocouple signal can be performed by the built-in temperature sensor. For more precise compensation, use the external RJC sensor (model B9108WA, sold separately). Shift Key Selects temperature” or RTD” unit. Terminal Adapter Provides screw terminals for connecting a temperature sensor such as a thermocouple and RTD when measuring temperature. When generating an RTD signal, a three-wire RTD signal can be output using the lead cables that come with the CA12E by short-circuiting the Lo-Lo terminals using the short-circuit bar that also comes with the CA12E. Plug for External RJC Sensor The RJC sensor is sold separately. Plug for AC Adapter Common for all CA11E, CA12E

Standard Accessories

Carrying Case

Power Supply

Four 1.5-V alkaline batteries (ANSI AA-size) or dedicated AC adapter (sold separately)

Battery Life

Approx. 55 hours When generating a signal continuously on alkaline batteries

Automatic Power-Off

Approx. 10 minutes (Can be canceled by DIP switch setting)

Generation Signal Level Setting

By four-digit up/down keys

Response of Generator

400? and RTD range : Approx. 20 milliseconds (from when the specified current is applied until when the output level falls within the specified accuracy)

Applied Voltage

42 V peak or less between each terminal and ground

Measurement Display

Approx. 1 update/sec.

Update interval Display

7 segments LCD

Operating Temperature/Humidity Range

0 to 50°C and 20 to 85%RH (no condensation)

Storage Temperature/Humidity Range

-20 to 50°C and 90%RH or less (no condensation)

Dimensions

Approx. 192 (W) x 92 (H) x 42 x (D) mm (Excluding protrusions)

Width

192 mm

Height

92 mm

Thickness

42 mm

Weight

Approx. 440 g (including batteries)

Additional Features

Automatic Power-off Choose either “rubber boot” or “carrying case” Compact and Lightweight Complete Protection (CA11E) Dip Switches (inside battery compartment) Longer Lead Cables Runs on 1.5 V AA-size Batteries or AC Adapter Simple and Easy Calibration

 

 

Honeywell Low-level analog input module backplane CC-TAIM01

Honeywell module

Honeywell module CC-TAIM01 PWA, PMIO LLMUX IOTA 64PT CE CC

Parameter Specification
Input / Output Model CC PAIM01, CU PAIM01
PMIO IOTA Models CC-TAIM01, CU-TAIM01
PMIO FTA Models (1) CC-TAMR04, CU-TAMT04

CC-TAMR04, CU-TAMT04

MC-TAMR04, MC-TAMT04

MU-TAMR04, MU-TAMT04

Input Type Thermocouple and / or RTD
Input channels 64 fully-isolated channel-to-channel, channel-to-PM,

and channel-to-power supply common in 16

channel increments.

Input scan rate 1 Second fixed by IOM (up to 64 channels/sec

max.)

Channel bandwidth 0 to 4.7 Hz (-3 dB)
Nominal input range (TC only) -20 to +100 millivolts
Maximum normal mode continuous input non-damaging (any

thermocouple type configured)

-10 to +10 volts (TC)

-1 to +2 Volts @ 100 milliamps (RTD)

Gain error (-20 to +100 millivolt range) 0.050% full scale max

Honeywell Low-level analog input module backplane CC-TAIM01

Model:

51309288-225 51309512-125 MC-TAMR03 51204162-175 51403988-150
51309218-175 51304362-150 51304337-150 51305348-100 51304453-150
80363972-150 51198947-100 51309276-150 51305508-200 51305348-100
51198947-100 51309512-175 51204160-175 51191593-100 51403427-275
51309241-125 51309288-375 51304419-150 51304532-150 51201557-150
51309241-175 51404305-375 51197593-100 51304511-200 51309290-125
51201420-005 51201420-010 51304754-150 51304337-150 51204160-175 51305348-100 51304453-150
51309276-150 51405038-175 51405040-175 51405039-175 51309204-175 51304362-150 51304754-150 80363969-150 80363972-150 80363975-150 51204172-175 51304453-15051305890-17551204162-175

51304449-500 INTECOLOR CRT EA
51304451-100 DO STANDBY MANUAL P WA EA
51304453-100 FTA, HLAI/STI COMP TERM MU-TAIH02 EA
51304453-150 FTA,HLAI/STI COMP TERM CC MC-TAIH02 EA
51304456-100 MONITOR 14IN EA 51196793-100
51304465-000 POWER CABLE (ORDER INDV. LENGTH) EA
51304467-100 FTA, LLMUX/SDI/SI PWR ADAPTER EA 51309204-175
51304467-150 FTA, LLMUX/SDI/SI PWR ADAPTER EA 51309204-175
51304472-100 PWA, NGI I/O EA
51304476-100 FTA, A/O COMPR TERM EA 51304476-175
51304476-125 A/O FTA, COMP CE MU-TAOX02 EA
51304476-150 FTA, A/O EA 51304476-175
51304476-175 FTA, A/O CCCE MC-TAOX02 EA
51304477-100 LLAI RTD MUX FTA EA 51309218-125
51304477-150 FTA,LLAI MUX RTD EA 51309218-175
51304478-100 FTA,LLAI MUX TC (SEE NOTES) EA
51304481-100 LLAI IOP ASSM MU-PAIL02 EA
51304481-150 LLAI IOP ASSM CC MC-PAIL02 EA
51304483-100 PWA, AO/IOP EA 51309152-175

There are a lot of models do not have the statistics, if you need, please contact me or send e-mail and phone

Honeywell Low-level analog input module CC-PAIM01

Honeywell module

Honeywell module CC-PAIM01 PWA MOD, LLAMUX G3 CE CC

Model Processing customized Scope Accuracy class
CC-PAIM01 Yes C300 1
Power Input Output  C300
60W 16 16  DCS

Professional to provide a Honeywell DCS card, integrity services, absolute guarantee is part of the original Honeywell new card, the scope of services involved S9000, plantscape, TDC2000 TDC3000 (US operation station), TPS (Gus operation station), PKS and Honeywell DCS distributed control system.

Honeywell Low-level analog input module CC-PAIM01

Model:

51309288-225 51309512-125 MC-TAMR03 51204162-175 51403988-150
51309218-175 51304362-150 51304337-150 51305348-100 51304453-150
80363972-150 51198947-100 51309276-150 51305508-200 51305348-100
51198947-100 51309512-175 51204160-175 51191593-100 51403427-275
51309241-125 51309288-375 51304419-150 51304532-150 51201557-150
51309241-175 51404305-375 51197593-100 51304511-200 51309290-125
51201420-005 51201420-010 51304754-150 51304337-150 51204160-175 51305348-100 51304453-150
51309276-150 51405038-175 51405040-175 51405039-175 51309204-175 51304362-150 51304754-150 80363969-150 80363972-150 80363975-150 51204172-175 51304453-15051305890-17551204162-175

51304449-500 INTECOLOR CRT EA
51304451-100 DO STANDBY MANUAL P WA EA
51304453-100 FTA, HLAI/STI COMP TERM MU-TAIH02 EA
51304453-150 FTA,HLAI/STI COMP TERM CC MC-TAIH02 EA
51304456-100 MONITOR 14IN EA 51196793-100
51304465-000 POWER CABLE (ORDER INDV. LENGTH) EA
51304467-100 FTA, LLMUX/SDI/SI PWR ADAPTER EA 51309204-175
51304467-150 FTA, LLMUX/SDI/SI PWR ADAPTER EA 51309204-175
51304472-100 PWA, NGI I/O EA
51304476-100 FTA, A/O COMPR TERM EA 51304476-175
51304476-125 A/O FTA, COMP CE MU-TAOX02 EA
51304476-150 FTA, A/O EA 51304476-175
51304476-175 FTA, A/O CCCE MC-TAOX02 EA
51304477-100 LLAI RTD MUX FTA EA 51309218-125
51304477-150 FTA,LLAI MUX RTD EA 51309218-175
51304478-100 FTA,LLAI MUX TC (SEE NOTES) EA
51304481-100 LLAI IOP ASSM MU-PAIL02 EA
51304481-150 LLAI IOP ASSM CC MC-PAIL02 EA
51304483-100 PWA, AO/IOP EA 51309152-175

There are a lot of models do not have the statistics, if you need, please contact me or send e-mail and phone

Yokogawa CA150 Calibrator

  • Place of Origin: Japan
  • Brand Name: YOKOGAWA
  • Model Number: CA150
  • Product Name: Yokogawa CA150 Calibrator
  • Safety: good
  • Quality: International Standard for Yokogawa CA150 Calibrator
  • Weight: 0.73kg
  • Power supply: 220-240V

CA150 signal source and measurement operations simultaneously:
In conventional calibration applications, multiple devices, such as a standard source, and multimeter resistance box. Now, with a single CA150, both to perform routine inspection and maintenance of the thermocouple, RTD and instrumentation, but also on the process equipment, such as transmitters, temperature controller and signal converter maintenance and diagnostic equipment.
CA150 high-precision, multi-functional source and measurement:
For DC voltage ranges source unit and measurement unit has 0.02% accuracy. A DC voltage, DC current, resistance, heat resistance, thermocouple (10 kinds) and frequency measurements. In DC1V, 10V, 500 ohm (excitation current 1mA) and RTD (excitation current 1mA) range, the minimum response time source 5ms

Specifications

 

Standard Accessories

None

Power Supply

6 AA size alkaline batteries AC adapter (sold separately) AC adapter specification: 100 to 240 VAC, 50/60 Hz, 1.4 A Dedicated NiMH battery (sold separately) OUTPUT: 12 VDC, 3 A

Auto power-off

Approx. 10 minutes; it can be canceled by setting.

Operating Temperature/Humidity Range

0 to 40°C, 20 to 80 % RH (no condensation)

Storage Temperature Range

-20 to 60°C 90%RH or less (no condensation)

External Dimensions

251 x 124 x 70 mm

Weight

Approx. 1000 g

Conforming Standards Safety

Softy EN61010-1 EMC EN 61326 Class B;EN 55011 Class B Group1 EN 61000-3-2; EN 61000-3-3, EN61326

 

Product Overview

Vertical Hand-Held Calibrator

Easy-to-hold vertical body is designed to make it intuitively easy to operate, as individual functions are accessed directly by pressing assigned keys. Using the main body case (model No. 93027) (sold separately), you can hang CA150 to your body or a handrail to keep it handy.

Simultaneous Source and Measurement for Process Devices

In conventional calibration applications, multiple devices such as a standard generator, dial resistor and multi-meter were required. Now with a single CA150 unit, it is possible to perform operation check at regular inspection and maintenance of thermocouples, RTDs and instruments, as well as maintenance and equipment diagnosis of process devices such as transmitters, thermostats and signal converters.

Loop Power Supply Function

It is possible to measure generated current signals while supplying loop power 24 VDC from a two-wire type transmitter (up to 22 mADC).

Highly Accurate and Multi-Functional Source and Measurement

High accuracy: 0.02% for the source unit and 0.02% for the measurement unit Source and Measurement functions: DCV voltage, DC mA, ohm, frequency and temperature (thermocouple, RTD) and 24 VDC power supply function for transmitters

Output Functions

Automatic Output Functions

  • Step sweep function This function changes the output in a staircase (step) pattern at fixed intervals.
  • Linear sweep function This function increases (or decreases) the output linearly with respect to the generated value.
  • Program sweep function This function outputs source setting values stored by the data memory function sequentially in the order they are stored in the memory.

Communication Functions

Serial interface RS232 D-Sub 9-pin connector

Memory Function

Data can be stored and loaded in setting memory (setting data) and data memory (source/measurement).

  • Setting memory This function saves/loads setting conditions. Up to 21 data items can be stored. Settings for (source/measurement) functions, ranges, generated values/measured values as well as setting mode conditions can be stored.
  • Data memory This function saves source and measure values displayed. Up to 100 data items can be stored. Storage date/time, (source/measurement) functions, ranges and generated values/measured values can be stored. Stored data can be checked on the display of the main unit as well as via communication.

 

Honeywell Redundant digital output module backplane CC-TDOB11

Honeywell module

Honeywell module CC-TDOB11 PWA, DO 24V BUSS IOTA RED 32 24V

Parameter Specification
Input / Output Model CC-PDOB01 – 24Volt Digital Output , Field Isolated, Bussed output

CU-PDOB01 – 24Volt Digital Output , Field Isolated, Bussed output

IOTA Models CC-TDOB11

CU-TDOB11

Non Redundant 6”
Redundant 12”
Output Channels 32
Load Voltage 30 VDC Maximum
Load Current Per Channel Per 8 Channels Per Module
(A group of 8 channels consists of

channels: 1-8, 9-16, 17-24, and 25-32)

One Short Condition(1)

Two Short Condition(1)

0.5A 3A 6A
0.5A 1.5A 6A
Galvanic Isolation 1500 VAC RMS or ±1500 VDC
On-State Voltage 24 V (typ), load current @ 0.5A
Off-State Voltage 0v VDC (max) (3.3VDC (max) indicated under no-load condition)
Off-State Leak Current

Turn-On/Turn-Off Time

Gap (0 current) of Output to Field on

Switchover

0.5 μA (max)

10 ms (max)

10 ms maximum (applies to Redundancy only)

Honeywell Redundant digital output module backplane CC-TDOB11

Professional to provide a Honeywell DCS card, integrity services, absolute guarantee is part of the original Honeywell new card, the scope of services involved S9000, plantscape, TDC2000 TDC3000 (US operation station), TPS (Gus operation station), PKS and Honeywell DCS distributed control system.

Model:

51309288-225 51309512-125 MC-TAMR03 51204162-175 51403988-150
51309218-175 51304362-150 51304337-150 51305348-100 51304453-150
80363972-150 51198947-100 51309276-150 51305508-200 51305348-100
51198947-100 51309512-175 51204160-175 51191593-100 51403427-275
51309241-125 51309288-375 51304419-150 51304532-150 51201557-150
51309241-175 51404305-375 51197593-100 51304511-200 51309290-125
51201420-005 51201420-010 51304754-150 51304337-150 51204160-175 51305348-100 51304453-150
51309276-150 51405038-175 51405040-175 51405039-175 51309204-175 51304362-150 51304754-150 80363969-150 80363972-150 80363975-150 51204172-175 51304453-15051305890-17551204162-175

51304449-500 INTECOLOR CRT EA
51304451-100 DO STANDBY MANUAL P WA EA
51304453-100 FTA, HLAI/STI COMP TERM MU-TAIH02 EA
51304453-150 FTA,HLAI/STI COMP TERM CC MC-TAIH02 EA
51304456-100 MONITOR 14IN EA 51196793-100
51304465-000 POWER CABLE (ORDER INDV. LENGTH) EA
51304467-100 FTA, LLMUX/SDI/SI PWR ADAPTER EA 51309204-175
51304467-150 FTA, LLMUX/SDI/SI PWR ADAPTER EA 51309204-175
51304472-100 PWA, NGI I/O EA
51304476-100 FTA, A/O COMPR TERM EA 51304476-175
51304476-125 A/O FTA, COMP CE MU-TAOX02 EA
51304476-150 FTA, A/O EA 51304476-175
51304476-175 FTA, A/O CCCE MC-TAOX02 EA
51304477-100 LLAI RTD MUX FTA EA 51309218-125
51304477-150 FTA,LLAI MUX RTD EA 51309218-175
51304478-100 FTA,LLAI MUX TC (SEE NOTES) EA
51304481-100 LLAI IOP ASSM MU-PAIL02 EA
51304481-150 LLAI IOP ASSM CC MC-PAIL02 EA
51304483-100 PWA, AO/IOP EA 51309152-175

There are a lot of models do not have the statistics, if you need, please contact me or send e-mail and phone

Honeywell Digital output module backplane CC-TDOB01

Honeywell module

Honeywell module CC-TDOB01 PWA, DO 24V BUSS IOTA 32 24V

Model Processing customized Scope Accuracy class
CC-TDOB01 Yes C300 1
Power Input Output  C300
60W 16 16  DCS

 

Honeywell Digital output module backplane CC-TDOB01

Professional to provide a Honeywell DCS card, integrity services, absolute guarantee is part of the original Honeywell new card, the scope of services involved S9000, plantscape, TDC2000 TDC3000 (US operation station), TPS (Gus operation station), PKS and Honeywell DCS distributed control system.

Model:

51309288-225 51309512-125 MC-TAMR03 51204162-175 51403988-150
51309218-175 51304362-150 51304337-150 51305348-100 51304453-150
80363972-150 51198947-100 51309276-150 51305508-200 51305348-100
51198947-100 51309512-175 51204160-175 51191593-100 51403427-275
51309241-125 51309288-375 51304419-150 51304532-150 51201557-150
51309241-175 51404305-375 51197593-100 51304511-200 51309290-125
51201420-005 51201420-010 51304754-150 51304337-150 51204160-175 51305348-100 51304453-150
51309276-150 51405038-175 51405040-175 51405039-175 51309204-175 51304362-150 51304754-150 80363969-150 80363972-150 80363975-150 51204172-175 51304453-15051305890-17551204162-175

51304449-500 INTECOLOR CRT EA
51304451-100 DO STANDBY MANUAL P WA EA
51304453-100 FTA, HLAI/STI COMP TERM MU-TAIH02 EA
51304453-150 FTA,HLAI/STI COMP TERM CC MC-TAIH02 EA
51304456-100 MONITOR 14IN EA 51196793-100
51304465-000 POWER CABLE (ORDER INDV. LENGTH) EA
51304467-100 FTA, LLMUX/SDI/SI PWR ADAPTER EA 51309204-175
51304467-150 FTA, LLMUX/SDI/SI PWR ADAPTER EA 51309204-175
51304472-100 PWA, NGI I/O EA
51304476-100 FTA, A/O COMPR TERM EA 51304476-175
51304476-125 A/O FTA, COMP CE MU-TAOX02 EA
51304476-150 FTA, A/O EA 51304476-175
51304476-175 FTA, A/O CCCE MC-TAOX02 EA
51304477-100 LLAI RTD MUX FTA EA 51309218-125
51304477-150 FTA,LLAI MUX RTD EA 51309218-175
51304478-100 FTA,LLAI MUX TC (SEE NOTES) EA
51304481-100 LLAI IOP ASSM MU-PAIL02 EA
51304481-150 LLAI IOP ASSM CC MC-PAIL02 EA
51304483-100 PWA, AO/IOP EA 51309152-175

There are a lot of models do not have the statistics, if you need, please contact me or send e-mail and phone

Yokogawa CA700 Calibrator

  • Brand Name: YOKOGAWA
  • Model Number: CA700
  • Product Name: Yokogawa CA700 Calibrator
  • Safety: good
  • Quality: International Standard for Yokogawa CA700 Calibrator
  • Weight: 2 kg
  • pressures measurement accuracy:±0.01%
  • current and voltage measurement:±0.015%

Portable Pressure Calibrator achieve the highest measurement accuracy. When measuring pressure, accuracy up to ± 0.01% of reading. When measuring the output and voltage / current, accuracy up to ± 0.015% of reading

 

CA700 Features:
1. has the highest accuracy in the same portable instrument
Yokogawa CA700 used to reflect the high-end technology of silicon resonant sensor, to achieve the highest measurement accuracy similar portable pressure calibrator. When measuring pressure, accuracy up to ± 0.01% of reading. And measuring the output voltage / current, accuracy up to ± 0.015% of reading. Must perform high-precision pressure and DC current input / output calibration field devices, CA700 fully meet this requirement. At the same price products, CA700 is the only source and measure simultaneously the current / voltage pressure calibrator.
2. The calibration has to improve the efficiency of the various functions
Due to internal pressure transmitters and pressure switches calibration step, CA700 can be stably and efficiently perform calibration operations. In addition, you can also record the data and the error rate before and after calibration, on-site equipment which helps to diagnose and determine the frequency of maintenance, can effectively improve the maintenance quality and maintenance efficiency.
3. Wide range of calibration to support various pressure transmitter
CA700 total of three models, the measurement range were -80k ~ 200kPa (kPa), – 80k ~ 1,000kPa, -80k ~ 3,500kPa. A CA700 meet different pressure transmitter calibration range, without having to buy a variety of pressure calibration according to the measurement range.
CA700 major markets:
Oil, gas, petrochemical, chemical, steel, paper, power, water and sewage treatment plant on-site equipment maintenance and repair
CA700 purposes:
The following debugging or for regular maintenance:
Differential pressure transmitter, pressure switch calibration and input / output performance test
Air tightness testing of pressure vessels and piping
Electro-pneumatic converter operation check etc.

Yokogawa CA51 Calibrator

  • Place of Origin: Japan
  • Brand Name: YOKOGAWA
  • Model Number: CA51
  • Product Name: Yokogawa CA51 Calibrator
  • Safety: good
  • Quality: International Standard for Yokogawa CA51 Calibrator
  • Weight: 0.73kg
  • Power supply: 220-240V

Yokogawa CA series calibrator spot: CA71, CA51, CA150, CA11E, CA12E, CA13, CA24, CA450

 

In practice, the sensor device very often needs many testing. CA71 portable calibrator lightweight, portable, multi-check function, and may occur simultaneously measure voltage, current, resistance, thermocouple (TC), thermal resistance (RTD), frequency and pulse signals. CA51 portable calibrator is the basis of type, in addition to thermocouple (TC), thermal resistance (RTD) measurement functions and communication functions, the other functions with the same CA71.
CA71 can occur DUT input signal, the output signal can also be detected when using the CA71, you need not worry about synchronization with other devices.

 

  • Source: DCV, DCA, resistance, RTD, TC (10 kinds), frequency, pulse
  • Measurement: DCV, DCA, ACV, resistance, RTD, TC (10 kinds), frequency, pulse
  • Features: both source and with a measuring function, a variety of useful functions, ease of operation, online communication
  • Options: AC adapter Mao Xie recorded 94012: for 100V AC, 94013: for 120V AC, B9108WB: for 220-240V AC Mau recorded holmium B9108WA RJ sensor, B9108XA accessories box 91017 communication cables?
Specifications

 

Signal generating unit response time Approximately 1 second (time between start of voltage change and when voltage enters accuracy range)
Signal generating unit voltage limiter Approximately 32 V
Signal generating unit current limiter Approximately 25 mA
Divided output (n/m) function Output = setting x (n/m) n = 0-m; m = 1-19; n < m
Auto-step output function n value sent automatically when n/m function selection is selected (two options: approximately 2.5 seconds/step or approximately 5 seconds/step)
Sweep function Sweep time (two options: approximately 16 seconds or approximately 32 seconds)
Memory function 50 value sets (generated and measured values are stored as value sets with the same address (up to 50 value sets can be stored))
Measuring unit maximum input Voltage terminal: 300 V AC Current terminal: 120 mA DC
Current terminal input protection Fuses: 125 mA/250 V
Measuring unit ground voltage Maximum 300 V AC
Measurement display updating rate Approximately once per second
Serial interface Enabled when communication cable (RS232) is connected; sold separately as optional accessory (CA71 only)
Display Segmented LCD (approximately 76 mm x 48 mm)
Backlight LED backlight; auto-off after one minute (from when LIGHT key is turned on)
Power supply Four AA alkaline batteries, or special AC adapter (sold separately)
Battery life Measurement off, output 5 V DC/10 kQ or greater: Approximately 40 hours Simultaneous signal generation/measurement, output 5 V DC/10 kQ or greater: Approximately 20 hours Simultaneous signal generation/measurement, output 20 mA/5 V: Approximately 12 hours (using alkaline batteries, with backlight off)
Consumed power Approximately 7 VA (using 100 V AC adapter)
Auto-power-off function Approximately 10 minutes (auto-power-off can be disabled through a DIP switch setting)
Conforming standards EN61010-1, EN61010-2-030 EN61010-031, EN61326-1, EN55011 Class B Group 1 EN61000-3-2, EN61000-3-3
Insulation resistance Across input terminal and output terminal, 500 V DC, 50 MQ or greater